Unified Development Ordinance

Sec. 3.2.5. General Building

Sec. 3.2.5. General Building aaron.sheppard… Tue, 05/23/2023 - 09:54
Image
 3-2-5-general-building-1
Image
 3-2-5-general-building-2
  OP-, OX-, NX-, CX- DX- IX-
A. Lot Dimensions
A1 Area (min) n/a n/a n/a
A2 Area (max) 10 acres (NX-only) n/a n/a
A3 Width (min) n/a n/a n/a
A4 Outdoor amenity area (min) 10% 10% 10%
B. Building/Structure Setbacks
B1 From primary street (min) 5' 3' 3'
B2 From side street (min) 5' 3' 3'
B3 From side lot line (min) 0' or 6' 0' or 6' 0’ or 6'
B4 From rear lot line (min) 0' or 6' 0’or 6' 0’or 6'
B4 From alley 5' 5' 5'
C. Parking Setbacks
C1 From primary street (min) 10' 10' 10'
C2 From side street (min) 10' 10' 10'
C3 From side lot line (min) 0' or 3' 0' or 3' 0’or 3'
C4 From rear lot line (min) 0' or 3' 0' or 3' 0’ or 3'
C5 From alley (min) 5' 5' 5'
D. Height
D1 Principal building (max) Set by district Set by district Set by district
D2 Accessory structure (max) 26' 26' 26'
E. Floor Heights
E1 Ground story height, floor to floor (min) 11' 13' 11'
E2 Upper story height, floor to floor (min) 9' 9' 9'
F. Transparency
F1 Ground story (min) 33% 50% 20%
F2 Upper story (min) 20% 20% 20%
F3 Blank wall (max) 30' 30' 50'
See Sec. 1.5.4.D “Building Setbacks” for specific building element requirements.
Supplement Number
28