Unified Development Ordinance

Sec. 3.6.1. Cottage Court

A. Description
A cottage court is a group of small detached houses, attached houses, townhouses (two-unit maximum per building), or tiny houses sharing a common courtyard. The courtyard enhances the character of the area through the provision of consolidated open space. A cottage court may be developed on individual lots or with a common form of ownership.
B. Districts Allowed In
 RX-, OX-, NX-, CX 
C. Building Types Allowed
 Detached house, Attached house, Townhouse (two-unit maximum per building), Tiny house 
  RX-, OX-, NX-, CX-
D. Site and Lot Dimensions
D1Net Site Area (min)13,000 sf
D2Site Width (min)90'
D3Site depth (min)90'
D4Site area per non-Tiny House dwelling unit over four (min)2,400 sf
D5Site area per Tiny House dwelling unit over four (min)1,800 sf
D6Dwelling units per site (max)30
D7Dwelling unit conditioned space (max - excluding qualifying basements)11,800 sf
D8Unconditioned space and accessory structure (individually and combined maximum per dwelling - excluding qualifying attics)2500 sf
D9Individual lot area (min)No min.
1A Tiny House may be no larger than 800 sf in building footprint and no more than 1200 sf in gross floor area.
2A detached accessory structure must be less than the gross floor area of the principal dwelling.
  RX-, OX-, NX-, CX-
E. Internal Courtyard
E1Area (min)1,600 sf
E2Width as measured parallel to primary street for first 15’ of site depth (min)120’
E3Courtyard area per non- Tiny House unit over four (min)400 sf
E4Courtyard area per Tiny House unit over four (min)200 sf
E5Setback from primary street (max)0'
F. Principal Building/Structure Setbacks (Site)
F1From primary street (min)10'
F2From side street (min)10'
F3From side site line (min)10'
F4From rear site line (min)20'
F5From alley (min5'
F6Building Separation (min)6'
F. Principal Building/Structure Setbacks (Lots)
F7From internal cottage court lot line (min)3'
F8From shared internal townhouse lot line (min)0'
G. Surface Parking Setbacks
G1From primary street if not screened from primary street by C3 yard or principal structure (min)90'
G2From primary street if screened from primary street by C3 yard or principal structure (min)50'
G3From side street (min)10'
G4From side lot line (min)5'
G5From rear lot line (min)5'
G6From alley (min)0'
H. Height
H1Non-Tiny House building height (max)30'
H2Tiny House building height (max)26'
H3Accessory structure height (max)26'
  1. Courtyard Requirements and Restrictions
    1. At least 60% of the courtyard must be one contiguous open space.
    2. Courtyard may not be parked or driven upon.
    3. One common building (detached house building type) not to exceed 3,000 square feet in gross floor area may be permitted in the courtyard under the following conditions:
      1. The common building may not be used as a dwelling.
      2. Uses within the common building must be accessory to the cottage court development.
      3. The common building shall not count towards the maximum number of dwelling units per site (Sec. 3.6.1.D.6.)
      4. Notwithstanding the forgoing, the common building must comply with all other requirements of Section 3.6.1.
    4. Inclusive of the common building, up to 20% of the minimum internal courtyard area (Sec. 3.6.1.E.1.) may be covered, however only 10% of the minimum internal courtyard area (Sec. 3.6.1.E.1.) may be enclosed.
    5. Stormwater detention wet ponds and dry ponds shall not count towards the minimum internal courtyard area (Sec. 3.6.1.E.1.) Green Stormwater Infrastructure (GSI) practices may be used to meet up to 50% of the minimum internal courtyard area (Sec. 3.6.1.E.1.)
    6. Tree Conservation Areas shall not be included as part of the minimum internal courtyard area (Sec. 3.6.1.E.1.)
    7. Retaining walls within the courtyard may be no taller than 4’ in height. Retaining walls that are 2’ or less in height may be spaced as close as 10’ apart. All other retaining walls must be spaced a minimum of 20’ apart.
    8. Pedestrian Access meeting the requirements of Section 8.3.5. shall be provided from each dwelling unit to the courtyard and any other common areas.
  2. Additional Requirements for Manufactured Homes to Qualify as Tiny Houses
     A Tiny House may be a Manufactured Home as defined Article 12.2. if it meets all of the following:
    1. The predominant roofline shall have a pitch of 5:12 or greater.
    2. The eave projections of the roof must not be less than ten inches (excluding roof gutters) unless the roof pitch is 8:12 or greater.
    3. The minimum height of the first-story exterior wall must be at least seven feet, six inches.
    4. Materials used as exterior wall covering shall be of a non-reflective material.
    5. Foundation skirting shall comply with the requirements set forth in Section 4.5.3.D.
    6. The Manufactured Home is no greater than 600 square feet in gross floor area.
Date of Adoption
TC Number
TC-10-24
Ordinance Number
2025-746-TC-490