Unified Development Ordinance

CHAPTER 3. MIXED USE DISTRICTS

CHAPTER 3. MIXED USE DISTRICTS aaron.sheppard… Mon, 05/08/2023 - 10:06

Article 3.1. General Provisions

Article 3.1. General Provisions aaron.sheppard… Mon, 05/08/2023 - 10:07

Sec. 3.1.1. District Intent Statement

Sec. 3.1.1. District Intent Statement aaron.sheppard… Tue, 05/23/2023 - 09:46

Sec. 3.1.1. District Intent Statements

Sec. 3.1.1. District Intent Statements aaron.sheppard… Mon, 07/03/2023 - 16:01
  1. Residential Mixed Use (RX-) 
    1. RX- is a mixed residential district intended to provide for a variety of residential building types and housing options at density in excess of 10 dwelling units per acre.
    2. RX- can serve as a land use transition between other mixed use districts and residential neighborhoods.
    3. RX- allows limited retail and services subject to use standards that limit the size and scale to the ground floor corner unit of an apartment building. 
  2. Office Park (OP-) 
    1. OP- is intended to preserve and provide land for office and employment uses.
    2. OP- can also serve as a land use transition between other mixed use districts and residential neighborhoods. 
  3. Office Mixed Use (OX-) 
    1. OX- is intended to provide for a variety of office and employment uses while allowing for housing and limited retail and service-related options. Limited retail and service-related options are allowed subject to use standards that restrict the size and scale of each use.
    2. OX- is not intended to provide for areas exclusively dominated by office or employment uses but provide for developments that balance employment and housing options with access to convenience retail services and goods.
    3. OX- can serve as a land use transition between other mixed use districts and residential neighborhoods. 
  4. Neighborhood Mixed Use (NX-) 
    1. NX- is intended to provide for a variety of residential, retail, service and commercial uses all within walking distance of residential neighborhoods.
    2. To limit the overall scale, NX- has a maximum lot size of 10 acres. Maximum height limits should be compatible with adjacent residential development. 
  5. Commercial Mixed Use (CX-) 
    1. CX- is intended to provide for a variety of residential, retail, service and commercial uses.
    2. While CX- accommodates commercial uses, the inclusion of residential and employment uses are strongly encouraged in order to promote live-work and mixed use opportunities. 
  6. Downtown Mixed Use (DX-) 
    DX- is intended to provide for intense mixed use development of the City’s downtown area. 
  7. Industrial Mixed Use (IX-) 
    1. IX- is intended to provide for a variety of light industrial and manufacturing uses while allowing for retail, service and commercial activity and limited housing opportunities. To help ensure that land is reserved for manufacturing and employment, residential uses are limited to the upper stories of mixed use buildings.
    2. IX- is not intended to provide for areas exclusively dominated by light industrial or manufacturing but provide for developments that incorporate commercial uses with housing, retail and service-related activity.
    3. IX- can serve as a land use transition between heavy industrial areas and mixed use districts.
Supplement Number
27

Sec. 3.1.2. District Components

Sec. 3.1.2. District Components aaron.sheppard… Tue, 05/23/2023 - 09:47
  1. Each Mixed Use District is comprised of one or more of the following components:
    1. Use and Base Dimensions (RX-, OP-, OX-, NX-, CX-, DX-, IX-);
    2. Height (-3, -4, -5, -7, -12, -20, -30, -40); and
    3. Frontage (-PK, -DE, -PL, -GR, -UL, -UG, -SH, -GP).
  2. A variety of Mixed Use Districts can be constructed by applying different height and frontage configurations as shown in the table below.
  3. Each Mixed Use District must include a height designation. A frontage is optional unless it has already been applied to the property and designated on the Official Zoning Map.
  4. Neighborhood transitions apply when adjacent to a residential district (see Article 3.5. Neighborhood Transitions).

table

 

Supplement Number
27

Article 3.2. Base Dimensional Standards

Article 3.2. Base Dimensional Standards aaron.sheppard… Mon, 05/08/2023 - 10:07

Sec. 3.2.1. Detached House

Sec. 3.2.1. Detached House aaron.sheppard… Tue, 05/23/2023 - 09:51
Image
 3-2-1-detached-house-1
Image
 3-2-1-detached-house-2
  RX-, OX-, NX-, CX- DX-
A. Lot Dimensions
A1 Area (min) 4,000 sf n/a
A2 Width (min) 45' n/a
B. Principal Building Setbacks
B1 From primary street (min) 10' 5'
B2 From side street (min) 10' 5'
B3 From side lot line (min) 5' 3'
B4 From rear lot line (min) 20' 10'
C. Accessory Structure Setbacks
C1 From primary street (min) 50' 30'
C2 From side street (min) 10' 5'
C3 From side lot line (min) 5' 3'
C4 From rear lot line (min) 5' 3'
C4 From alley 4' or 20' min 4' or 20' min
D. Height
D1 Principal building (max) 40'/3 stories 40'/3 stories
D2 Accessory structure (max) 25' 25'
E. Transparency
E1 Ground story (min) 20% 20%
E2 Upper story (min) 15% 15%
E3 Blank wall area (max) 35' 35'
See Sec. 1.5.4.D "Building Setbacks" for specific building element requirements.

Sec. 3.2.2. Attached House

Sec. 3.2.2. Attached House aaron.sheppard… Tue, 05/23/2023 - 09:51
Image
 3-2-2-attached-house-1
Image
 3-2-2-attached-house-2
  RX-, OX-, NX-, CX- DX-
A. Lot Dimensions
A1 Area (min) 4,000 sf n/a
A2 Width (min) 45' n/a
B. Principal Building Setbacks
B1 From primary street (min) 10' 5'
B2 From side street (min) 10' 5'
B3 From side lot line (min) 5' 3'
B4 From rear lot line (min) 20' 10'
C. Accessory Structure Setbacks
C1 From primary street (min) 50' 30'
C2 From side street (min 10' 5'
C3 From side lot line (min) 5' 3'
C4 From rear lot line (min) 5' 3'
C4 From alley 4' or 20' min 4' or 20' min
D. Height
D1 Principal building (max) 40'/3 stories 40'/3 stories
D2 Accessory structure (max) 25' 25'
E. Transparency
E1 Ground story (min) 20% 20%
E2 Upper story (min) 15% 15%
E3 Blank wall area (max) 35' 35'
See Sec. 1.5.4.D "Building Setbacks" for specific building element requirements.

Sec. 3.2.3. Townhouse

Sec. 3.2.3. Townhouse aaron.sheppard… Tue, 05/23/2023 - 09:52
Image
 3-2-3-townhouse-1
Image
 3-2-3-townhouse-2
  RX-, OX-, NX-, CX- DX-
A. Site Dimensions
A1 Area (min) 3,300 sf n/a
A2 Width (min) 45' n/a
A3 Outdoor Amenity Area 10% 10%
B. Lot Dimensions
B1 Area (min) n/a n/a
B2 Width (min) 16' n/a
C. Building/Structure Setbacks
C1 From primary street (min) 10' 5'
C2 From side street (min) 10' 5'
C3 From side site boundary line (min) 10' 6'
C4 From rear site boundary line (min)ii 20' 6'
C5 From alley (min)iii 4' or 20' min 4' or 20' min
C6 Internal building separation 10' 10'
D. Parking Setbacksiv
D1 From primary street (min) 20' 20'
D2 From side street (min) 10' 10'
D3 From side lot line (min) 0' 0'
D4 From rear lot line (min) 3' 3'
D5 From alley (min) 4' 4'
E. Height
E1 Principal building (max) Set by district Set by district
E2 Accessory structure (max) 26' 26'
E3 Residential Infill rules may apply (see Sec. 2.2.7) no yes
F. Transparency
F1 Ground story (min) 20% 20%
F2 Upper story (min) 15% 15%
F3 Blank wall area (max) 35' 35'

See Sec. 1.5.4.D “Building Setbacks” for specific building elements requirements.
i A townhouse development containing only two dwelling units shall be regulated by the standards of Sec. 3.2.2., Attached House, however: (a) a minimum site area per unit of one-half the area required by Sec. 3.2.2.A1. is required; (b) Sec. 3.2.3.B. shall still control provided a minimum site width equal to the dimensions specified by Sec. 3.2.2.A2. is met; and (c) Sec. 3.2.2.B3. shall only apply to the non-party wall side lot line.
ii A permanently recorded open lot or common area lot of at least 20 feet in width may be used to satisfy Sec. 3.2.3.C4.
iii Garages (or a portion thereof) must either be located 4 feet from the travel lane of an alley or rear access drive or be a minimum of 20 feet from the alley or rear access drive. Where parking spaces are located between the garage and the alley or rear access drive, the garage must be located at least 20 feet from the travel lane of an alley or rear access drive.
iv Parking setbacks shall not apply to driveways serving individual dwelling units or shared between two dwelling units.

Supplement Number
28

Sec. 3.2.4. Apartment

Sec. 3.2.4. Apartment aaron.sheppard… Tue, 05/23/2023 - 09:53
Image
 3-2-4-apartment-1
Image
 3-2-4-apartment-2
  RX-, OX-, NX-, CX- DX-
A. Lot Dimensions
A1 Area (min) 7,500 sf n/a
A2 Area (max) 10 acres (NX- only) n/a
A3 Width (min) n/a n/a
A4 Outdoor amenity area (min) 10% 10%
B. Building/Structure Setbacks
B1 From primary street (min) 5' 5'
B2 From side street (min) 5' 5'
B3 From side lot line (min) 0' or 6' 0' or 6'
B4 From rear lot line (min) 0' or 6' 0’ or 6’
B5 From alleyi 4' or 20' min 4' or 20' min
C. Parking Setbacks
C1 From primary street (min) 10' 10'
C2 From side street (min) 10' 10'
C3 From side lot line (min) 0' 0'
C4 From rear lot line (min) 0' 0'
C5 From alley, garage only (min) 4' 4'
D. Height
D1 Principal building (max) Set by district Set by district
D2 Accessory structure (max) 26' 26'
E. Transparency
E1 Ground story (min) 20% 20%
E2 Upper story (min) 15% 15%
E3 Blank wall (max) 35' 35'
See Sec. 1.5.4.D “Building Setbacks” for specific building elements requirements
iGarages (or a portion thereof) must either be located 4 feet from the travel lane of an alley or rear access drive or be a minimum of 20 feet from the alley or rear access drive. Where parking spaces are located between the garage and the alley or rear access drive, the garage must be located at least 20 feet from the travel lane of an alley or rear access drive.
Supplement Number
28

Sec. 3.2.5. General Building

Sec. 3.2.5. General Building aaron.sheppard… Tue, 05/23/2023 - 09:54
Image
 3-2-5-general-building-1
Image
 3-2-5-general-building-2
  OP-, OX-, NX-, CX- DX- IX-
A. Lot Dimensions
A1 Area (min) n/a n/a n/a
A2 Area (max) 10 acres (NX-only) n/a n/a
A3 Width (min) n/a n/a n/a
A4 Outdoor amenity area (min) 10% 10% 10%
B. Building/Structure Setbacks
B1 From primary street (min) 5' 3' 3'
B2 From side street (min) 5' 3' 3'
B3 From side lot line (min) 0' or 6' 0' or 6' 0’ or 6'
B4 From rear lot line (min) 0' or 6' 0’or 6' 0’or 6'
B4 From alley 5' 5' 5'
C. Parking Setbacks
C1 From primary street (min) 10' 10' 10'
C2 From side street (min) 10' 10' 10'
C3 From side lot line (min) 0' or 3' 0' or 3' 0’or 3'
C4 From rear lot line (min) 0' or 3' 0' or 3' 0’ or 3'
C5 From alley (min) 5' 5' 5'
D. Height
D1 Principal building (max) Set by district Set by district Set by district
D2 Accessory structure (max) 26' 26' 26'
E. Floor Heights
E1 Ground story height, floor to floor (min) 11' 13' 11'
E2 Upper story height, floor to floor (min) 9' 9' 9'
F. Transparency
F1 Ground story (min) 33% 50% 20%
F2 Upper story (min) 20% 20% 20%
F3 Blank wall (max) 30' 30' 50'
See Sec. 1.5.4.D “Building Setbacks” for specific building element requirements.
Supplement Number
28

Sec. 3.2.6. Mixed Use Building

Sec. 3.2.6. Mixed Use Building aaron.sheppard… Tue, 05/23/2023 - 09:54
Image
 3-2-6-mixed-use-building-1
Image
 3-2-6-mixed-use-building-2
  OP-, OX-, NX-, CX-, IX- DX-
A. Lot Dimensions
A1 Area (min) n/a n/a
A2 Area (max) 10 acres (NX- only) n/a
A3 Width (min) n/a n/a
A4 Outdoor amenity area (min) 10% 10%
B. Building/Structure Setbacks
B1 From primary street (min) 5' 3'
B2 From side street (min) 5' 3'
B3 From side lot line (min) 0' or 6' 0' or 6'
B4 From rear lot line (min) 0' or 6' 0' or 6'
B5 From alley 5' 5'
C. Parking Setbacks
C1 From primary street (min) 10' 10'
C2 From side street (min) 10' 10'
C3 From side lot line (min) 0' or 3' 0' or 3'
C4 From rear lot line (min) 0' or 3' 0' or 3'
C5 From alley (min) 5' 5'
D. Height
D1 Principal building (max) Set by district Set by district
D2 Accessory structure (max) 26' 26'
E. Floor Heights
E1 Ground story height, floor to floor (min) 13' 15'
E2 Upper story height, floor to floor (min) 9' 9'
F. Transparency
F1 Ground story (min) 50% 66%
F2 Upper story (min) 20% 20%
F3 Blank wall (max) 20' 20'
See Sec. 1.5.4.D "Building Setbacks" for specific building element requirements.
Supplement Number
28

Sec. 3.2.7. Civic Building

Sec. 3.2.7. Civic Building aaron.sheppard… Tue, 05/23/2023 - 09:55
Image
 3-2-7-civic-building-1
Image
 3-2-7-civic-building-2
  RX-, OP-, OX-, NX-, CX-, IX- DX-
A. Lot Dimensions
A1 Area (min) n/a n/a
A1 Area (max) 10 acres (NX- only) n/a
A2 Width (min) n/a n/a
A3 Outdoor amenity area (min) 10% 10%
B. Building/Structure Setbacks
B1 From primary street (min) 10' 5'
B2 From side street (min) 10' 5'
B3 From side lot line (min) 0' or 6' 0' or 6'
B4 From rear lot line (min) 0' or 6' 0' or 6'
B4 From alley (min) 5' 5'
C. Parking Setbacks
C1 From primary street (min) 10' 10'
C2 From side street (min) 10' 10'
C3 From side lot line (min) 0' or 3' 0' or 3'
C4 From rear lot line (min) 0' or 3' 0' or 3'
C4 From alley (min) 5' 5'
D. Height
D1 Principal building (max) Set by district Set by district
D2 Accessory structure (max) 26' 26'
See Sec. 1.5.4.D "Building Setbacks" for specific building element requirements.
Supplement Number
28

Sec. 3.2.8. Open Lot

Sec. 3.2.8. Open Lot aaron.sheppard… Tue, 05/23/2023 - 09:55
Image
 3-2-8-open-lot-1
Image
 3-2-8-open-lot-2
  RX-, OP-, OX-, NX-, CX-, IX- DX-
A. Lot Dimensions
A1 Area (min) 5,000 sf n/a
A2 Width (min) 50' n/a
A3 Building coverage (max) 15% 15%
B. Building/Parking Setbacks
B1 From primary street (min) 10' 10'
B2 From side street (min) 10' 10'
B3 From side lot line (min) 10' 10'
B4 From rear lot line (min) 10' 10'
B4 From alley (min) 10' 10'
C. Height
C1 All building/structures (max) 40'/3 stories 40'/3 stories
D. Allowed Building Elements
Porch, stoop
Balcony
Gallery, awning
See Sec. 1.5.4.D "Building Setbacks" for specific building element requirements.
Supplement Number
28

Sec. 3.2.9. Tiny House

Sec. 3.2.9. Tiny House aaron.sheppard… Tue, 05/23/2023 - 09:56
Image
 3-2-9-tiny-house-1
Image
 3-2-9-tiny-house-2
  RX-, OX-, NX-, CX- DX-
A. Lot Dimensions
A1 Area (min) 2,000 sf  n/a
A2 Width (min) 25' n/a
B. Building Setbacks
B1 From primary street (min) 10' 5'
B2 From side street (min) 10' 5'
B3 From side lot line (min) 5' 3'
B4 From rear lot line (min) 10' 10'
B5 From alley 4' or 20' min 4' or 20' min
C. Height 
C1 Principal building (max) 26'/2 stories 26'/2 stories

See Sec. 1.5.4.D "Building Setbacks" for specific building element requirements.

D. Additional Requirements for Manufactured Homes to Qualify as Tiny Houses
A Tiny House may be a Manufactured Home as defined in Article 12.2. if it meets all of the following:

  1.  The predominant roofline shall have a pitch of 5:12 or greater.
  2. The eave projections of the roof must not be less than ten inches (excluding roof gutters) unless the roof pitch is 8:12 or greater.
  3. The minimum height of the first-story exterior wall must be at least seven feet, six inches.
  4. Materials used as exterior wall covering shall be of a non-reflective material.
  5. Foundation skirting shall comply with the requirements set forth in Section 4.5.3.D.
  6. The Manufactured Home is no greater than 600 square feet in gross floor area.
Supplement Number
28

Article 3.3. Height Requirements

Article 3.3. Height Requirements aaron.sheppard… Mon, 05/08/2023 - 10:08

Sec. 3.3.1. Applicability

Sec. 3.3.1. Applicability aaron.sheppard… Tue, 05/23/2023 - 09:57
  1. Each Mixed Use District must include one of the following height designations. The designation establishes the maximum height in stories and feet for each mixed use district. For example, CX-5 has a maximum height limit of 5 stories and 80 feet.
    -3            3 stories / 50 feet max
    -4            4 stories / 68 feet max
    -5            5 stories / 80 feet max
    -7             7 stories
    -12           12 stories
    -20          20 stories
    -30          30 stories
    -40          40 stories
  2. The height requirements apply to apartments, general buildings, mixed use buildings and civic buildings. Maximum heights for detached house, tiny house, attached house, townhouse and open lot are set forth in Article 3.2. Base Dimensional Standards.
  3. The minimum height requirements apply only to the Urban Frontages. The Urban Frontages include the following: Green, Green Plus, Urban Limited, Urban General and Shopfront. Civic buildings are exempt from the minimum height requirements.
  4. The Transit Overlay District (TOD) allows for building heights in excess of the maximum height of the underlying district for certain uses or development types as defined in Section 5.5.1 Transit Overlay District.
  5. When a mezzanine or mezzanines comprise less than 50% of the floor area of the room or space in which they are located, they are not considered a story. When a mezzanine or mezzanines comprise 50% or more of the floor area of the room or space in which they are located, they are considered a story. If a building is taller than five stories, mezzanines are permitted within only two stories of that building. Any additional intermediate level otherwise qualifying as a mezzanine is considered an additional story. If a building has five or fewer stories, there is no limit on the number of stories in that building that may contain a mezzanine.
Supplement Number
28

Sec. 3.3.2. Building Height Standards

Sec. 3.3.2. Building Height Standards aaron.sheppard… Tue, 05/23/2023 - 09:57
Image
 3-3-2-building-height-standards
  District -3 -4 -5 -7 -12 -20 -30 -40
A. Max Height
A1 Building height (max stories) 3 4 5 7 12 20 30 40
A2 Building height (max feet) 50' 68' 80'          
B. Min Height (Urban Frontages Only)
B1 Building height (min stories) street facing façade(s) at min n/a n/a n/a 2 2 3 3 3
B2 Height (cumulative min % of building width(s)) n/a n/a n/a 75% 75% 75% 75% 75%
B3 Depth of min height from front building façade into lot (min) n/a n/a n/a 30' 45' 60' 60' 60'
Supplement Number
27

Sec. 3.3.3. Building Massing Standards

Sec. 3.3.3. Building Massing Standards aaron.sheppard… Tue, 05/23/2023 - 09:58
  1. Intent
    The intent of the building massing regulations is to manage the impact of tall buildings located near the public right-of-way. Stepbacks are intended to avoid a canyon effect by providing access to light and air at street level, and mitigating wind impacts. The massing regulations also produce a consistent street wall and visually reduce the perceived scale of a building.
  2. Stepbacks 
    Buildings of 13 or more stories are required to place a stepback above the 1st floor or 25’, whichever is greater, but below the 13th floor
    1. The stepback is only required on building faces adjoining the public street.
    2. The depth of a required stepback may be reduced by 5 feet if the cornice line of the stepback matches the cornice line of an adjacent building.
  3. Floor Plate Size
    Above the 12th story, buildings are allowed 30,000 square feet of buildable area per story. The total amount of allowable square footage above the 12th story is thus defined as 30,000 square feet multiplied by the number of floors above 12 that are allowed per the site’s zoning. Larger floor plate size will result in fewer floors, whereas smaller floor plates will allow for taller towers. Buildings may not exceed the number of floors allowed by the underlying zoning district.
  4. Design Alternate Findings
    The Planning Commission or Design Review Commission performing the quasi-judicial duties of the Planning Commission (as designated by the City Council), after conducting a duly noticed quasi-judicial evidentiary hearing in accordance with Sec. 10.2.17., shall approve an alternate building massing standard, if all of the following findings are satisfied:
    1. The approved alternate is consistent with the intent of the building massing regulations;
    2. The approved alternate uses an architectural base distinguishable from the building above that enhances the pedestrian environment through a change in material, fenestration, ornamentation, rhythm, or other sculpting of the base.
    3. If the approved alternate proposes a building setback behind the sidewalk in lieu of a required stepback, the resulting open space includes pedestrian amenities such as seating areas, trees and landscaping or outdoor dining.
    4. The building uses other architectural treatments to mitigate wind impacts, increase light at pedestrian level, and visually reduce the scale of the building.
    5. The building does not cause undue shadow impacts on public spaces, amenity areas, and surrounding streets.
Image
 3-3-3-d-5-building-massing-standards
  Height of Building  Up to 12 Stories 13 to 20 Stories 21 to 30 Stories 21 to 40 Stories
E. Massing
E1 2nd (or 25', whichever is greater) - 12th story stepback (min)  n/a 12' 12' 12'
F. Towers
F1 Allowable area per tower above 12 stories (max)  n/a 30,000 sf per allowable floor 30,000 sf per allowable floor 30,000 sf per allowable floor
F2 Spacing between towers - floors above 12 stories on adjacent sites (min)*  n/a 30' 50' 60'

* Building separation is measured orthogonally to the wall plane.

Supplement Number
28

Article 3.4. Frontage Requirements

Article 3.4. Frontage Requirements aaron.sheppard… Mon, 05/08/2023 - 10:08

Sec. 3.4.1. Purpose and Intent

Sec. 3.4.1. Purpose and Intent aaron.sheppard… Tue, 05/23/2023 - 09:58

Frontages link a desired development pattern with specific form requirements that mandate the type of development desired along the street edge. Frontages place different requirements from the base dimensional standards. Where there is a conflict between the base dimensional standards and the frontage requirements, the frontage requirements control.

Image
 3-4-1-a-parkway

A. Parkway (-PK)
The -PK Frontage is intended to provide a heavily landscaped buffer between the roadway and adjacent development to ensure a continuous green corridor along the street right-of-way.

Image
 3-4-1-b-detached

B. Detached (-DE)
The -DE Frontage is intended for areas adjacent to roadways transitioning from residential to commercial. Accommodates neighborhood-scaled, low intensity commercial uses while maintaining the residential character of the street right of-way.

Image
 3-4-1-c-parking-limited

C. Parking Limited (-PL)
The -PL Frontage is intended for areas where access to buildings by automobile is desired but where some level of walkability is maintained. Permits a maximum of 2 bays of on-site parking with a single drive aisle between the building and the street right-of-way.

Image
 3-4-1-d-green

D. Green (-GR)
The -GR Frontage is intended for areas where it is desirable to locate buildings close to the street, but where parking between the building and street is not permitted. Requires a landscaped area between the building and the street right of-way.

Image
 3-4-1-e-urban-limited

E. Urban Limited (-UL)
The -UL Frontage is intended for areas where parking between the building and street is not allowed. Buildings abut the street and sidewalk but to balance the needs of both the pedestrian and automobile lower street wall continuity is required.

Image
 3-4-1-f-urban-general

F. Urban General (-UG)
The -UG Frontage is also intended for areas where parking between the building and street is not allowed. Buildings abut the street and sidewalk but higher street wall continuity is required than the -UL Frontage.

Image
 3-4-1-g-shopfront

G. Shopfront (-SH)
The -SH Frontage is for intended for areas where the highest level of walkability is desired. The -SH Frontage is intended to create a “main street” type of environment; therefore, mixed use buildings are the primary building type allowed.

Image
 3-4-1-h-green-plus

H. Green Plus (GP)
Intended for areas where it is desirable to locate buildings close to the street, but where parking between the building and street is not permitted. Requires a treelined area between the building and the street right-of-way.

Supplement Number
27

Sec. 3.4.2. General Requirements

Sec. 3.4.2. General Requirements aaron.sheppard… Tue, 05/23/2023 - 09:59
  1. Urban Frontages
    The Urban Frontages include the following: Green, Green Plus, Urban Limited, Urban General and Shopfront.
  2. Design of Parking Structures on Urban Frontages
    1. The ground story of structured parking must have active uses (such as, but not limited to, residential, commercial, office or civic space) located between the parking structure and any public sidewalk along a primary street or where the structured parking is within 30 feet of any other public sidewalk notwithstanding the existence of an intervening lot, unless the intervening lot is improved with an active use between the sidewalk and the structured parking.
    2. Ramping in the parking structure shall be internalized or otherwise screened.
    3. The ground floor facade treatment of any parking structure façade (building materials, windows and architectural detailing) shall be continued on upper stories. Upper stories shall be designed with a maximum horizontal and vertical rhythm of 30 feet that aligns with other elements along the block face.
    4. The maximum blank wall area (see Section 1.5.10.) of any parking structure façade shall be 20’. This requirement does not apply to screening elements affixed to the façade and used to meet the requirements of Sec. 7.2.5.F.
  3. Preexisting Conditions
    1. All buildings, structures, pedestrian accesses, streetscapes and vehicular surface areas existing at the time that the frontage is first applied to the property shall not be deemed a zoning nonconformity solely because of frontage requirements. Replacement and repair of buildings, structures, pedestrian accesses, streetscapes and vehicular surface areas existing at the time that the frontage is first applied to the property may be made provided all of the following are met:
      1. Replacement is like for like.
      2. The replacement conforms to all provisions of this UDO except, frontage requirements.
      3. The damage or destruction is caused by means other than voluntary actions.
      4. Reconstruction and repair, not including interior work, shall not exceed 50% of the replacement cost immediately prior to the damage or destruction. Replacement cost shall be determined in accordance with Sec. 10.3.3.G.4 and 5.
      5. Reconstruction or repair is commenced with a valid building permit or zoning permit within 12 months of the date of such damage or destruction.
    2. Lots and sites subject to build-to requirements that contain pre-existing buildings and maintain pre-existing buildings and which add additions to existing buildings that singularly or collectively comprise no more than 25% of the gross floor area existing at the time the build-to requirements became applicable to the property, or 1,000 square feet, whichever is greater, are allowed to expand the building anywhere within their minimum setbacks, without deference to the build-to requirements. All other frontage requirements, if any, shall apply.
    3. Lots and sites subject to build-to requirements that contain pre-existing buildings and maintain pre-existing buildings and which either add additions to existing buildings in excess of those allowed by item number 2. above or construct any new additional buildings on the lot shall conform to the following build to requirements. All other frontage requirements, if any, shall apply.
      1. Additions
        Expansion of an existing building that is unable to meet the required build-to percentage must comply with the following provisions:
        1. Street-Fronting: Addition
          Additions to the front of an existing building would be allowed. The addition does not have to extend into the build-to area nor does it have to meet the required build-to percentage for the lot.
          Image
           3-4-2-c-1
        2. Rear: Addition
          Image
           3-4-2-c-2

          Rear additions are not allowed until the required build-to percentage for the lot has been met except when the addition is used exclusively for one or more of the following: loading areas, storage, kitchens, repair facilities (including bays for motor vehicles) and mechanical equipment.
          Image
           3-4-2-c-3
          Image
           3-4-2-c-4
        3. Non-street Side: Addition
          Non-street Side Additions are allowed where the side addition is at least as close to the build-to as the existing building because the extension increases the width of the building and does not set back any further than the existing building.
      2. New Buildings
        Image
         3-4-2-c-5

        Where a new building is being constructed on a lot with an existing building that does not meet the build-to percentage requirement, the following provisions comply:
        1. Street-Fronting: New Building
          Image
           3-4-2-c-6

          All new buildings must be placed in the build-to range until the required build-to percentage requirement has been met for the lot.
        2. Rear: New Building
          Image
           3-4-2-c-7

          New buildings located in the rear of existing buildings are not allowed until the required build-to percentage requirements have been met for the lot.
        3. Non-street Side: New Building
          New buildings located outside of the build-to range are not allowed until the required build-to percentage requirements have been met for the lot.
    4. The Planning Director may, in accordance with Sec. 10.2.17., reduce the build-to requirement, subject to the findings set forth in Sec. 1.5.6.D.
    5. The streetscape requirements shall not apply whenever a Tier 1 site plan is applicable in accordance with Sec.10.2.8; in all other instances, the streetscape requirements shall apply. The additional parking limitations of this article shall be applied in accordance with Sec. 7.1.1.B.4. Related parking requirements of this UDO shall be in accordance with Sec. 7.1.1.B.
    6. Lots subject to build-to requirements that contain buildings existing at the time the frontage regulations were first applied to the property may, without deference to the build-to requirements, make voluntary renovations or alterations changing the exterior appearance of such buildings, including vertical expansions, that do not enlarge the footprint of the existing buildings, when done in accordance with the transparency and streetscape requirements of this UDO, and the pedestrian access requirements of this UDO when the costs of improvements exceed cumulatively $10,000 in any calendar year. Voluntary demolitions or tear-downs shall be replaced with building improvements that comply with the regulations of the applicable build-to requirements and all other frontage requirements.
    7. In the event that buildings, structures, pedestrian accesses, streetscapes and vehicular surface areas existing at the time that the frontage is first applied to the property is damaged or partially destroyed, by exercise of eminent domain, riot, fire, accident, explosion, flood, lightning, wind or other calamity or natural cause to the extent of more than 50% of the replacement cost immediately prior to such damage, such buildings, structures, pedestrian accesses, streetscapes and vehicular surface areas shall not be restored unless either the replacement will conform to all regulations of this UDO or a special use permit is issued by the Board of Adjustment for the restoration. Replacement cost shall be determined in accordance with Sec. 10.3.3 G.4. and 5.
      Before a request for the special use permit is granted, the Board of Adjustment must show that all of the following are met:
      1. The applicable standards of this section have been met;
      2. All of the showings of Sec. 10.2.9.E. have been met; and
      3. The requested repair, reconstruction, or restoration will not be injurious to property or improvements in the affected area.
Supplement Number
28

Sec. 3.4.3. Parkway (-PK)

Sec. 3.4.3. Parkway (-PK) aaron.sheppard… Tue, 05/23/2023 - 10:00
Image
 3-4-3-parkway
A. Description
  Provides for a heavily landscaped buffer between the roadway and adjacent development to ensure a continuous green corridor along the street right-of-way.
B. Building Types Allowed
  Detached house (see Sec. 3.2.1.) General building (see Sec. 3.2.5.)
  Attached house (see Sec. 3.2.2.) Mixed use building (see Sec. 3.2.6.)
  Townhouse (see Sec. 3.2.3.) Civic building (see Sec. 3.2.7.)
  Apartment (see Sec. 3.2.4.) Open lot (see Sec. 3.2.8.)
  Tiny House (see Sec. 3.2.9.)  
C. Additional Setbacks
C1 Building setback from primary street (min) 50'
C2 Parking setback from primary street (min) 50'
D. Pedestrian Access
D1 Pedestrian access required (minimum of 1 per lot) yes
D2 Pedestrian access way spacing (max) 300'
D3 Width of pedestrian access way (min/max) 10'20'
D4 A road or driveway with a sidewalk at least 6 feet in width may substitute for a required pedestrian access way  
D5 Direct pedestrian access is required from the public sidewalk to the primary entrance of the building  
E. Protective Yard Landscaping
E1 The 50-foot protective yard must be landscaped in accordance with Sec. 5.3.1.F. (SHOD-1 requirements) or Sec. 5.3.1.H. for expansions and additions.  
F. Protective Yard Encroachments
F1 Driveways see Sec. 8.3.5.
F2 Ground signs see Article 7.3.
F3 Pedestrian access way  
G. Streetcape Requirement
  Sidewalk & tree lawn see Sec. 8.5.9.G.
Supplement Number
28

Sec. 3.4.4. Detached (-DE)

Sec. 3.4.4. Detached (-DE) aaron.sheppard… Tue, 05/23/2023 - 10:01
Image
 3-4-4-detached
A. Description
Intended for areas adjacent to roadways transitioning from residential to commercial. Accommodates neighborhood-scaled, low intensity commercial uses while maintaining the residential character of the street right-of-way.
B. Building Types Allowed
  Detached house (see Sec. 3.2.1.) Apartment (see Sec. 3.2.4.)
  Attached house (see Sec. 3.2.2.) Civic building (see Sec. 3.2.7.)
  Townhouse (see Sec. 3.2.3.) Open lot (see Sec. 3.2.8.)
  Tiny House (see Sec. 3.2.9.)  
C. Additional Buildings Setbacks
C1 Street Setback (Minimum and Maximum) applies (see Sec. 2.2.7.)  
D. Additional Parking Limitations
D1 No on-site parking or vehicular surface area permitted between the building and the street, with the exception of driveways serving single or two-unit living.  
E. Pedestrian Access
E1 Primary street-facing entrance required (min of 1 per building)  
E2 Direct pedestrian access is required from the public sidewalk to the primary street-facing entrance of the building  
F. Facade Articulation
F1 Front wall length without offset (max) 40'
F2 Front wall offset length and depth (min) 10'
G. Height Limitations1
G1 Height limit for frontage (max) 3 stories/50'
H. Streetcape Requirement
  Residential see Sec. 8.5.9.D

1Height limitations not applicable to buildings utilizing the Frequent Transit Development Option Height Bonus.

Supplement Number
28

Sec. 3.4.5. Parking Limited (-PL)

Sec. 3.4.5. Parking Limited (-PL) aaron.sheppard… Tue, 05/23/2023 - 10:01
Image
 3-4-5-parking-limited
A. Description
  Intended for areas where access to buildings by automobile is desired but where some level of walkability is maintained. Permits a maximum of 2 bays of on-site parking with a single drive aisle between the building and the street right-of-way.
B. Building Types Allowed  
  Townhouse (see Sec. 3.2.3.) Mixed use building (see Sec. 3.2.6.)
  Apartment (see Sec. 3.2.4.) Civic building (see Sec. 3.2.7.)
  General building (see Sec. 3.2.5.) Open lot (see Sec. 3.2.8.)
C. Build-to
C1 Primary street build-to (min/max) Minimum setback based on base dimensional standards for the specific building type/100
C2 Building width in primary build-to (min) 50%
C3 Side street build-to (min/max) 0'/100'
C4 Building width in side build-to (min) 25%
D. Height Limitations
D1 Height limit for frontage (max) 7 stories/90'
E. Additional Parking Limitations
E1 A maximum of 2 bays of on-site parking with a single drive aisle is permitted between the building and the street.  
F. Pedestrian Access
F1 Primary street-facing entrance required (min of 1 per building)  
F2 Direct pedestrian access is required from the public sidewalk to the primary street-facing entrance of the building  
G. Streetscape Requirement
  Main Street; or see Sec. 8.5.9.A.
  Mixed Use; or see Sec. 8.5.9.B.
  Commercial; or see Sec. 8.5.9.C.
  Multi-way; or see Sec. 8.5.9.E.
  Parking. see Sec. 8.5.9.F.
The determination of the appropriate streetscape treatment will be made by the
Planning Director, based on the existing built context and character.

 

Supplement Number
28

Sec. 3.4.6. Green (-GR)

Sec. 3.4.6. Green (-GR) aaron.sheppard… Tue, 05/23/2023 - 10:02
Image
 3-4-6-green
A. Description
Intended for areas where it is desirable to locate buildings close to the street, but where parking between the building and street is not permitted. Requires a landscaped area between the building and the street right-of-way. Amenity area may be located between the landscaped area and the building.
B. Building Types Allowed
  Townhouse (see Sec. 3.2.3.) Mixed use building (see Sec. 3.2.6.)
  Apartment (see Sec. 3.2.4.) Civic building (see Sec. 3.2.7.)
  General building (see Sec. 3.2.5.) Open lot (see Sec. 3.2.8.)
C. Build-to
C1 Primary street build-to (min/max) 20'/50'
C2 Building width in primary build-to (min) 50%
C2 Side street build-to (min/max) 20'/50'
C4 Building width in side build-to (min) 35%
D. Additional Parking Limitations
D1 Parking setback from primary street (min) 20'
D2 No on-site parking or vehicular surface area permitted between the building and the street  
E. Pedestrian Access
E1 Primary street-facing entrance required yes
F. Landscape Area
F1 The landscape area must be landscaped in accordance with Type C3 street protective yard standards (see Sec. 7.2.4.B.). However, in no instance shall a 3.5’ wall be substituted for shrubs. see Sec. 7.2.4.B.
G. Landscape Yard Encroachments
G1 Driveways see Sec. 8.3.5.
G2 Ground Signs see Article 7.3. Signs
G3 Pedestrian access way  
H. Streetscape Requirement
H1 Commercial see Sec. 8.5.9.C.
Supplement Number
28

Sec. 3.4.7. Urban Limited (-UL)

Sec. 3.4.7. Urban Limited (-UL) aaron.sheppard… Tue, 05/23/2023 - 10:02
Image
 3-4-7-urban-limited
A. Description
  Intended for areas where parking between the building and street is not allowed. Buildings abut the street and sidewalk but to balance the needs of both the pedestrian and automobile lower street wall continuity is required.
B. Building Types Allowed
  Townhouse (see Sec. 3.2.3.) Mixed use building (see Sec. 3.2.6.)
  Apartment (see Sec. 3.2.4.) Civic building (see Sec. 3.2.7.)
  General building (see Sec. 3.2.5.) Open lot (see Sec. 3.2.8.)
C. Build-to
C1 Primary street build-to (min/max) 0'/20'
C2 Building width in primary build-to (min) 50%
C3 Side street build-to (min/max) 0'/20'
C4 Building width in side build-to (min) 25%
D. Additional Parking Limitations
D1 No on-site parking or vehicular surface area permitted between the building and the street  
E. Pedestrian Access
E1 Primary street-facing entrance required yes
F. Streetscape Area
  Main Street; or see Sec. 8.5.9.A.
  Mixed Use. see Sec. 8.5.9.B.
Supplement Number
28

Sec. 3.4.8. Urban General (-UG)

Sec. 3.4.8. Urban General (-UG) aaron.sheppard… Tue, 05/23/2023 - 10:03
Image
 3-4-8-urban-general
A. Description
  Intended for areas where parking between the building and street is not allowed. Buildings abut the street and sidewalk but higher street wall continuity is required than the -UL Frontage.
B. Building Types Allowed
  Townhouse (see Sec. 3.2.3.) Mixed use building (see Sec. 3.2.6.)
  Apartment (see Sec. 3.2.4.) Civic building (see Sec. 3.2.7.)
  General building (see Sec. 3.2.5.) Open lot (see Sec. 3.2.8.)
C. Build-to
C1 Primary street build-to (min/max) 0'/20'
C2 Building width in primary build-to (min) 70%
C3 Side street build-to (min/max) 0'/20'
C4 Building width in side build-to (min) 35%
D. Additional Parking Limitations
D1 Parking setback from primary street (min) 30’
D2 No on-site parking or vehicular surface area permitted between the building and the street  
E. Pedestrian Access
E1 Primary street-facing entrance required yes
F. Streetscape Area
  Main Street; or see Sec. 8.5.9.A.
  Mixed Use. see Sec. 8.5.9.B.
Supplement Number
28

Sec. 3.4.9. Shopfront (-SH)

Sec. 3.4.9. Shopfront (-SH) aaron.sheppard… Tue, 05/23/2023 - 10:03
Image
 3-4-9-shopfront
A. Description
Intended for areas where the highest level of walkability is desired. The -SH Frontage is intended to create a "main street" type of environment; therefore, mixed use buildings are the primary building type allowed.
B. Building Types Allowed
  Mixed use building (see Sec. 3.2.6.)  
  Civic building (see Sec. 3.2.7.)  
  Open lot (see Sec. 3.2.8.)  
C. Build-to
C1 Primary street build-to (min/max) 0'/15'
C2 Building width in primary build-to (min) 80%
C3 Side street build-to (min/max) 0'/15'
C4 Building width in side build-to (min) 40%
D. Additional Parking Limitations
D1 Parking setback from primary street (min) 30’
D2 No on-site parking or vehicular surface area permitted between the building and the street  
E. Pedestrian Access
E1 Primary street-facing entrance required yes
F. Streetscape Area
  Main Street see Sec. 8.5.9.B.
Supplement Number
28

Sec. 3.4.10. Green Plus (-GP)

Sec. 3.4.10. Green Plus (-GP) aaron.sheppard… Tue, 05/23/2023 - 10:03
Image
 3-4-1-h-green-plus
A. Description
Intended for areas where it is desirable to locate buildings close to the street, but where parking between the building and street is not permitted. Requires a tree-lined area between the building and the street right-of-way.
B. Building Types Allowed
  Townhouse (see Sec. 3.2.3.)  
  Mixed use building (see Sec. 3.2.6.)  
  Apartment (see Sec. 3.2.4.)  
  Civic building (see Sec. 3.2.7.)  
  General building (see Sec. 3.2.5.)  
  Open lot (see Sec. 3.2.8.)  
C. Build-to
C1 Primary street build-to (min/max) 30'/50'
C2 Building width in primary build-to (min) 50%
C3 Side street build-to (min/max) 20'/50'
C4 Building width in side build-to (min) 35%
D. Additional Parking Limitations
D1 Parking setback from primary street (min) 30’
D2 No on-site parking or vehicular surface area permitted between the building and the street  
E. Pedestrian Access
E1 Primary street-facing entrance required yes
F. Streetscape Area
F1 Driveways see Sec. 8.3.5.
F2 Ground signs see Article 7.3
F3 Pedestrian access way  
G. Streetscape Requirement
G1 Commercial see Sec. 8.5.2.C
H. Landscape Requirements for Primary Street
H1 Four shade trees are required per 100 linear feet. Required landscaping must meet the design and installation requirements of Sec. 7.2.7. Preservation of an eligible existing tree as set forth in Section 7.2.7.E. will count as two new trees for purposes of this requirement.  
I. Use Requirements in RX
  Commercial uses in RX are limited to the first floor of a corner unit in an Apartment building type located at the intersection of 2 public streets. Commercial uses in RX cannot exceed 4,000 square feet in total per lot. These provisions control over any provisions in the -TOD overlay district.  
Supplement Number
28

Article 3.5. Neighborhood Transitions

Article 3.5. Neighborhood Transitions aaron.sheppard… Mon, 05/08/2023 - 10:09

Sec. 3.5.1. Applicability

Sec. 3.5.1. Applicability aaron.sheppard… Tue, 05/23/2023 - 10:04
  1. The following neighborhood transition standards apply in the Mixed Use and Campus Districts when the following occurs:
    1. The site immediately abuts a district boundary of an R-1, R-2, R-4, R-6, or R-10 district, where the abutting property is vacant or contains an existing detached house, tiny house, or attached house; or
    2. The site immediately abuts a district boundary of a Planned Development (PD-) district where the abutting property is vacant or contains a detached house, tiny house, or attached house and any of the following apply:
      1. Has a residential reference district; or
      2. Does not permit general and mixed-use buildings; or
      3. Does not permit commercial and industrial uses.
  2. Zone B does not apply to sites 50 feet or less in depth. In such cases, Zone C starts immediately adjacent to the Zone A protective yard.
  3. Neighborhood transitions do not apply to single-unit living, two-unit living or cottage court uses within detached house, tiny house attached house or townhouse building types where the proposed or existing building height is 50 feet or less.
  4. Zones B and C do not apply to detached house, tiny house attached house, townhouse or apartment building types in a mixed-use district where the proposed or existing building height is 50 feet or less, provided the proposed use is also permitted in RX- and adheres to any applicable RX- and underlying zoning district use standards.
  5. Zones B and C do not apply to detached house, tiny house, attached house, townhouse or apartment building types in the TOD, including for Residential districts where RX- standards are used (See Sec. 5.5.1)
  6. Where an intervening alley is located between the residential property and the Mixed Use District or Campus District, the transition regulations apply. One half of the width of the alley shall be included in the required transition yard measurement and shall be first applied to the required width of Zones A and B and then to Zone B. In all cases, landscaping, fences and walls shall not be required where there is an intervening alley.
  7. In addition to the alley transition described in paragraph D, the Historic Alley Transition described in Section 3.5.6 is available where an alley lies between a residential district and a mixed use district and the following conditions are met:
    1. The alley abuts or lies within a National Register Historic District; and
    2. The mixed-use parcel has not within the last two years contained a structure that is, or was, individually designated as a local, State, or national historic landmark.
Supplement Number
28

Sec. 3.5.2. Transition Zones

Sec. 3.5.2. Transition Zones aaron.sheppard… Tue, 05/23/2023 - 10:05
  1. Zone A: Protective Yard
    1. Intent
      Intended to buffer and screen. Consists of vegetative landscaping and wall or fence. No buildings or structures allowed.
    2. Location
       
      Immediately abutting district boundary line.
    3. Width
       
      Varies (depends on protective yard type applied).
  2. Zone B: Use Restricted
    1. Intent
      Intended to be occupied by open areas and low intensity uses, such as surface parking, alleys, landscaping, playgrounds, outdoor dining, community serving buildings and service-related structures.
    2. Location
       Located between Zone A and Zone C. Zone B starts at the inside edge of the Zone A protective yard (edge furthest from the district boundary line) and ends 50 feet from the district boundary line.
    3. Width
       50 feet from the district boundary line.
  3.  Zone C. Height and Form
    1. Intent
      Intended to restrict the height and form of development so as to decrease the impact of new multi-story  structures.
    2. Location
      Located beyond and adjacent to Zone B. Zone C extends from 50 to 100 feet from district boundary line. When Zone B does not exist, Zone C starts at the inside edge of the Zone A protective yard (edge furthest from the district boundary line).
    3. Width
      50 to 100 feet from the district boundary line. When Zone B does not exist, Zone C extends a maximum of 50 feet from inside edge of the Zone A protective yard (edge furthest from the district boundary line).
Image
 3-5-2-c-3
Supplement Number
27

Sec. 3.5.3. Zone A: Protective Yard

Sec. 3.5.3. Zone A: Protective Yard aaron.sheppard… Tue, 05/23/2023 - 10:05
  1. Type 1: Narrow(10 feet) 
    1. Width
      A Type 1 protective yard must be an average width of at least 10 feet.
    2. Installation Requirements
      A Type 1 protective yard must include the following:
      1. A wall between 6.5 and 9 feet in height;
      2. Four shade trees per 100 lineal feet;
      3. Three understory trees per 100 lineal feet; and
      4. 40 shrubs per 100 lineal feet.
  2. Type 2: Narrow(20 feet)
    1. Width
      A Type 2 protective yard must be an average width of at least 20 feet.
      Image
       3-5-3-b-1
    2. Installation Requirements
      A Type 2 protective yard must include the following:
      1. A wall or fence between 6.5 and 9 feet in height;
      2. Five shade trees per 100 lineal feet; 
      3. Four understory trees per 100 lineal feet; and 
      4. 30 shrubs per 100 lineal feet.
  3. Type 3: Narrow(50 feet)
    1. Width
      A Type 3 protective yard must be an average width of at least 50 feet.
    2. Installation Requirements
      A Type 3 protective yard must include the following:
      1. Six shade trees per 100 lineal feet;
      2. Five understory canopy trees per 100 lineal feet; and
      3. 60 shrubs per 100 lineal feet.
    3. Optional Provisions
      1. A fence or wall between 6.5 and 8 feet in height may be installed.
      2. In lieu of planting required shrubs, a berm with a minimum height of 3 feet may be installed. 
    4. Permitted uses
      1. Landscaping, fences, walls and berms.
      2. Swales, underground detention facilities and bioretention facilities. Detention facilities must be located at least 20 feet from the district boundary line. Landscaping quantities specified in Sec. 3.5.3.C.2. above may not be reduced.
  4. Design and Installation
    1. A required protective yard may be replaced with a tree conservation area that meets the requirements of Article 9.1.Tree Conservation.
    2. Required landscaping in a protective yard must meet the design and installation requirements of Sec. 7.2.4.
    3. In no case shall required landscaping exceed 30% of the total lot area, see Sec. 7.2.2.D.
    4. Protective yards must meet the location requirements of Sec. 7.2.4.C.
    5. Fences, walls and berms located in a protective yard must meet the requirements of Sec. 7.2.4.D. Fences, walls and berms cannot be located in a protective yard when the protective yard is also a tree conservation area.
Supplement Number
28

Sec. 3.5.4. Zone B: Use Restrictions

Sec. 3.5.4. Zone B: Use Restrictions aaron.sheppard… Tue, 05/23/2023 - 10:06
  1. Permitted Activity 
    1. Intended to buffer Protective yard, landscaping, fence, wall.
    2. Garden.
    3. Outdoor dining (not between the hours of 10 PM and 6 AM).
    4. Service area.
    5. Accessory garage, storage area.
    6. Park, playground.
    7. Stormwater detention.
    8. Surface parking lot.
    9. Path, walkway, sidewalk.
    10. Alley.
      Image
       3-5-4-a-1
      Image
       3-5-4-a-2
  2. Civic Building and Accessory Structures
    1. ​​​​​​​An accessory structure can be no more than 14 feet in height and must be located at least 15 feet from the district boundary line.
    2. Building walls parallel to the district boundary line can be no longer than 75 feet.
    3. Buildings and structures must be spaced apart to maintain views. There must be a minimum of 40 feet between buildings and structures.
  3. Service Areas
    Trash collection, trash compaction, recycling collection and other similar service areas must be located at least 25 feet from the district boundary line.
Supplement Number
28

Sec. 3.5.5. Zone C: Height and Form

Sec. 3.5.5. Zone C: Height and Form aaron.sheppard… Tue, 05/23/2023 - 10:06
  1. Permitted Activity
    All structures and uses allowed in the zoning district are permitted in Zone C.
  2. Height
    1. No structure can be more than 40 feet in height at the Zone C line, as measured from the average pre-development grade measured along the Zone C line.
    2. Height can increase subject to a 45 degree height plane measured from a height of 40 feet at the Zone C line, extending upward one foot for every additional foot of setback into the site.
    3. The height plane applies up to 100 feet from the district boundary line.
  3. Wall Articulation
    The rear facade of the building that faces the residential property as described in Sec. 3.5.1.A. is subject to a maximum blank wall area of 30 feet as calculated in Sec. 1.5.10. The blank wall area provisions are not subject to an Design Alternate.
    Image
     3-5-5-c
Supplement Number
28

Sec. 3.5.6. Historic Alley Transition

Sec. 3.5.6. Historic Alley Transition aaron.sheppard… Tue, 05/23/2023 - 10:07
  1. Intent
    The Historic Alley Transition is intended to ensure a graduated height transition between the National Register District and nearby mixed-use development; to avoid abrupt contrasts of scale between the residential properties in a National Register District and mixed use structures; to avoid incompatible development facing the residential properties in a National Register District; and to improve historic alleys with active frontages and uses more beneficial to the National Register District.
  2. Extent
    The Historic Alley Transition extends from the residential parcel property line across the intervening alley and into the mixed-use parcel for a distance of 50 feet from the residential parcel property line.
  3. Restrictions
    In addition to the other restrictions imposed by this Unified Development Ordinance, the following additional restrictions apply to construction within the Historic Alley Transition:
    1. Content
      This Historic Alley Transition Area may contain vegetative landscaping, walls, fences, gardens, paths, walkways, sidewalks, surface parking, parks, playgrounds, stormwater detention, outdoor dining areas associated with residential uses, accessory structures compliant with the limits set forth in Paragraph 3.5.4.B, service areas compliant with the limits set forth in Paragraph 3.5.4.C, detached houses, tiny houses, attached houses, townhouses, apartments, general  buildings, mixed use buildings, and open lots.
    2. Height
      No portion of a detached house, tiny house, attached house, townhouse, apartment, general building, mixed use building, or other structure that lies within the Historic Alley Transition shall exceed the maximum building height applicable to the residential parcel across the alley from the mixed use parcel, as specified in the residential zoning district or applicable overlay district or otherwise. For this purpose only, height shall be measured from the elevation of the alley.
    3. Uses
      Any use extending into the Historic Alley Transition must be one of the residential uses permitted in R-10 Districts.
    4. Setback
      Notwithstanding any base dimensional standards or frontage requirements that might otherwise apply, any building constructed in the Historic Alley Transition shall be set back at least 10 feet from the alley-facing property line of the mixed use parcel. This setback must contain a sidewalk of at least 5-foot width immediately adjacent to the alley right-of-way, over which a permanent public access easement must be granted. This immediately adjacent sidewalk will be separated from the street by sharply contrasting materials. The sidewalk shall not exceed the elevation of alley by more than two inches, unless a mountable curb is installed. No building element or other item or obstruction may extend into or be placed in this sidewalk portion of the setback. The remainder of the setback shall meet the requirements of Section 3.5.2.A and 3.5.3.A, except
      1. If the remainder of the setback is less than 10 feet in width, the protective yard need not contain shade trees; and
      2. No wall is required when a building immediately abuts the protective yard.
    5. Design Requirements
      1. ​​​​​​​Structured parking is permitted in the Historic Alley Transition, but residential uses must screen the structured parking and conceal the structured parking (other than an entrance with no visible point source lighting) consistent with the regulations contained in Section 3.4.2.B, except that all upper levels of the parking structure that face the alley shall also be screened by residential uses.
      2. An alley-facing entrance is required at least every 100 feet, regardless of building type. There must be direct pedestrian access to that entrance from the adjoining sidewalk.
      3. The alley-facing facade is subject to a maximum blank wall area of 30 feet as calculated in Sec. 1.5.10. The blank wall area provisions are not subject to an Design Alternate.
      4. Private residential garage parking that satisfies the requirements of Section 1.5.12 is permitted along the alley as part of a detached house, tiny house, attached house, or townhouse within the Historic Alley Transition. Such parking must be concealed behind a garage door of not more than 12 foot width. Any standard contained in Section 1.5.12 that is applied must be consistent with G.S. 160D-702(b).
      5. Entrances to structured parking and private residential garage parking shall not occupy more than 50% of the parcel’s linear alley frontage.
      6. The requirements of Section 3.5.4.C apply, though residential trash and recycling bins may be collected from the alley if placed according to the applicable rules. Ground-mounted mechanical equipment other than individual residential HVAC units must be placed according to Section 3.5.4.C.
Supplement Number
28

Article 3.6. Additional Housing Patterns

Article 3.6. Additional Housing Patterns aaron.sheppard… Mon, 05/08/2023 - 10:09
Supplement Number
27

Sec. 3.6.1. Cottage Court

Sec. 3.6.1. Cottage Court aaron.sheppard… Tue, 05/23/2023 - 10:07
A. Description
A cottage court is a group of small detached houses, attached houses, townhouses (two-unit maximum per building), or tiny houses sharing a common courtyard. The courtyard enhances the character of the area through the provision of consolidated open space. A cottage court may be developed on individual lots or with a common form of ownership.
B. Districts Allowed In
  RX-, OX-, NX-, CX  
C. Building Types Allowed
  Detached house, Attached house, Townhouse (two-unit maximum per building), Tiny house  
    RX-, OX-, NX-, CX-
D. Site and Lot Dimensions
D1 Net Site Area (min) 13,000 sf
D2 Site Width (min) 90'
D3 Site depth (min) 90'
D4 Site area per non-Tiny House dwelling unit over four (min) 2,400 sf
D5 Site area per Tiny House dwelling unit over four (min) 1,800 sf
D6 Dwelling units per site (max) 30
D7 Dwelling unit gross floor area (max)1 1,800 sf
D8 Detached accessory structure footprint (max)2 450 sf
D9 Individual lot area (min) No min.
1A Tiny House may be no larger than 800 sf in building footprint and no more than 1200 sf in gross floor area.
2A detached accessory structure must be less than the gross floor area of the principal dwelling.
    RX-, OX-, NX-, CX-
E. Internal Courtyard
E1 Area (min) 1,600 sf
E2 Width as measured parallel to primary street for first 15’ of site depth (min)1 20’
E3 Courtyard area per non- Tiny House unit over four (min) 400 sf
E4 Courtyard area per Tiny House unit over four (min) 200 sf
E5 Setback from primary street (max) 0'
F. Principal Building/Structure Setbacks (Site)
F1 From primary street (min) 10'
F2 From side street (min) 10'
F3 From side site line (min) 10'
F4 From rear site line (min) 20'
F5 From alley (min 5'
F6 Building Separation (min) 6'
F. Principal Building/Structure Setbacks (Lots)
F7 From internal cottage court lot line (min) 3'
F8 From shared internal townhouse lot line (min) 0'
G. Surface Parking Setbacks
G1 From primary street if not screened from primary street by C3 yard or principal structure (min) 90'
G2 From primary street if screened from primary street by C3 yard or principal structure (min) 50'
G3 From side street (min) 10'
G4 From side lot line (min) 5'
G5 From rear lot line (min) 5'
G6 From alley (min) 0'
H. Height
H1 Non-Tiny House building height (max) 30'
H2 Tiny House building height (max) 26'
H3 Accessory structure height (max) 26'
  1. Courtyard Requirements and Restrictions
    1. At least 60% of the courtyard must be one contiguous open space.
    2. Courtyard may not be parked or driven upon.
    3.  One common building (detached house building type) not to exceed 3,000 square feet in gross floor area may be permitted in the courtyard under the following conditions:
      1. The common building may not be used as a dwelling.
      2. Uses within the common building must be accessory to the cottage court development.
      3. The common building shall not count towards the maximum number of dwelling units per site (Sec. 3.6.1.D.6.)
      4. Notwithstanding the forgoing, the common building must comply with all other requirements of Section 3.6.1.
    4. Inclusive of the common building, up to 20% of the minimum internal courtyard area (Sec. 3.6.1.E.1.) may be covered, however only 10% of the minimum internal courtyard area (Sec. 3.6.1.E.1.) may be enclosed.
    5. Stormwater detention wet ponds and dry ponds shall not count towards the minimum internal courtyard area (Sec. 3.6.1.E.1.) Green Stormwater Infrastructure (GSI) practices may be used to meet up to 50% of the minimum internal courtyard area (Sec. 3.6.1.E.1.)
    6. Tree Conservation Areas shall not be included as part of the minimum internal courtyard area (Sec. 3.6.1.E.1.)
    7. Retaining walls within the courtyard may be no taller than 4’ in height. Retaining walls that are 2’ or less in height may be spaced as close as 10’ apart. All other retaining walls must be spaced a minimum of 20’ apart.
    8. Pedestrian Access meeting the requirements of Section 8.3.5. shall be provided from each dwelling unit to the courtyard and any other common areas.
  1. Additional Requirements for Manufactured Homes to Qualify as Tiny Houses
     
    A Tiny House may be a Manufactured Home as defined Article 12.2. if it meets all of the following:
    1. The predominant roofline shall have a pitch of 5:12 or greater.
    2. The eave projections of the roof must not be less than ten inches (excluding roof gutters) unless the roof pitch is 8:12 or greater.
    3. The minimum height of the first-story exterior wall must be at least seven feet, six inches.
    4. Materials used as exterior wall covering shall be of a non-reflective material.
    5. Foundation skirting shall comply with the requirements set forth in Section 4.5.3.D.
    6. The Manufactured Home is no greater than 600 square feet in gross floor area.

Sec. 3.6.2. Accessory Dwelling

Sec. 3.6.2. Accessory Dwelling aaron.sheppard… Tue, 05/23/2023 - 10:08
  1. Purpose and Objectives
    The Accessory Dwelling housing pattern provides for the development of accessory dwelling units on a lot as an accessory use to a principal use.
  2. Base Standards Apply
    Except as specifically set forth in this section, the allowed uses, the dimensional requirements, height limits and general development standards of the underlying zoning district apply.
  3. Definition
    An Accessory Dwelling Unit (ADU) is a self-contained dwelling unit that is located on the same lot as another principal use. Accessory Dwelling Units may be detached, attached, or internal to the principal use. Only residential uses are permitted in Accessory Dwelling Units.
  4. Accessory Dwelling Unit Regulations
    In accordance with this section, an accessory dwelling unit shall conform with the following development regulations:
    1. An ADU shall be located on the same lot as a principal use and meet both of the following:
      1. The gross floor area of the accessory dwelling shall be less than the gross floor area of the total principal use; and
      2. Shall be affixed to or constructed on a permanent foundation and not be a manufactured home or moveable structure except as specified in Sec. 3.2.6.D.6. below;
    2. There shall be no more than one ADU on the same lot as a principal use unless it is located in a Frequent Transit Area as shown on the City’s Comprehensive Plan which would then allow for up to two ADUs on the same lot as a principal use. However in the Frequent Transit Area, only one ADU can be attached to the principal building. In the case of a townhouse development only one ADU is permitted per townhouse;
    3. It shall be accessed by a lockable external entrance;
    4. Ownership of an ADU shall not be transferred apart from its principal building;
    5. It shall meet all relevant standards and requirements of the UDO, provided however accessory dwelling units shall not be subject to Sections 6.7.1. and 6.7.2. with the exception of 6.7.2.B.
    6. An Accessory Dwelling Unit may be a Manufactured Home as defined in Article 12.2 if it meets all of the following:
      1. The predominant roofline shall have a pitch of 5:12 or greater.
      2. The eave projections of the roof must not be less than ten inches (excluding roof gutters) unless the roof pitch is 8:12 or greater.
      3. The minimum height of the first-story exterior wall must be at least seven feet, six inches.
      4. Materials used as exterior wall covering shall be of a non-reflective material.
      5. Foundation skirting shall comply with the requirements set forth in Section 4.5.3.D.
      6. The Manufactured Home is no greater than 600 square feet in gross floor area.
    7. Unless attached thereto by a common wall, an ADU must be separated by at least 6’ from any other building on the lot.
    8. All ADU entrances must be externally accessible by pedestrians from either the driveway, street and/or alley from which the lot takes access.
    9. Encroachments into setbacks are permitted pursuant to Section 1.5.4.D.
    10. Vertical encroachments are permitted pursuant to Sections 1.5.7.D.2. and 1.5.7.D.3.g.
  5. Description
    An Accessory Dwelling Unit (ADU) is a self-contained dwelling unit that is located on the same lot as a principal building that meets the regulations identified in Section 3.3.2. An ADU may be located above a garage. ADUs may be detached, attached, or internal to the principal building. Only residential uses are permitted in ADUs.
F. Districts Allowed In
RX-, OX-, NX-, CX
G. Building Specifications
G1 Gross Floor Area (max)1 800
H. Detached ADU Setbacks
H1 From primary street (min) Must be located at or behind the front wall of the principal building
H2 From side street (min) 10’
H3 From side lot line (min)2 5’
H4 From rear lot line (min)3 5’
H5 From alley (min) 4’without parking / 20’ with parking
I. Height
I1 Overall height (max) 26’

1Gross floor area shall include all conditioned space. Attached unconditioned space shall be included in the calculation of accessory structure floor area.
2For townhouse lots, H3 shall only apply to the side site boundary.
3For townhouse lots, H4 shall only apply to the rear site boundary.

Supplement Number
27

Article 3.7. Frequent Transit Development Option

Article 3.7. Frequent Transit Development Option aaron.sheppard… Mon, 05/08/2023 - 10:10
  1. The Frequent Transit Development Option allows for additional housing and employment space in locations near current and planned frequent transit service. A Frequent Transit Area refers to areas slated for bus or other transit service where the time between buses will be 15 minutes or less during peak service periods and must be mapped in the City’s Comprehensive plan as such.
  2. The option allows for an additional two stories of height, up to a maximum of five stories, for apartment and mixed use building types. It allows only one additional story of height, up to a maximum of four stories, for general buildings. This additional height applies in Frequent Transit Areas, but not BRT Areas.
  3. The option also includes requirements to improve walkability. Any building that incorporates the additional height must adhere to the Urban Limited frontage unless otherwise mapped with the Urban General, Shopfront, Green or Green Plus frontage which then controls. Any building that incorporates the height bonus may not incorporate a drive-thru.
Supplement Number
27

Sec. 3.7.1. Frequent Transit Development Option

Sec. 3.7.1. Frequent Transit Development Option aaron.sheppard… Tue, 05/23/2023 - 10:09
    RX-, OX-, NX-, CX-, IX-
A. Building Types
A1 Applicable Building Types Detached House, Attached House, Townhouse, Apartment, Mixed Use Building, and General Building types
B. Lot Dimensions
B1 Area (min) 2,000 sf
B2 Lot width (min) 45’
B3 Depth (min) 60’
B4 Density (max) n/a
B5 Outdoor Amenity Area (min) (Does not apply to Tiny House, Detached House, or Attached House) 10%
    RX-, OX-, NX-, CX-, IX-
C. Principal Building Setbacks
C1 From primary street (min) 10’
C2 From side street (min) 10’
C3 From side lot line (min) 1 0’ or 5’
C4 From rear lot line (min) 2 15’
C5 From Alley (min) * 4’ or 20’
D. Height
D1 Detached/Attached Principal Building (max) 40'/3 stories
D2 Townhouse/Apartment Principal Building (max) Set by District
D3 Tiny House (max) 26’/2 stories
D4 Accessory Structure (max) 26’
D5 Height Bonus for properties zoned for 3-stories4 The Apartment and Mixed-Use building types containing residential uses may be a maximum of five stories not to exceed 80’ in height. For developments containing residential uses, a number of units equal to at least twenty percent (20%) of the residential units established in newly allowed stories as the result of this height bonus shall be affordable for households earning sixty percent (60%) of the Area Median Income or less for a period of no less than 30 years from the date of issuance of a certificate of occupancy. The General Building type may be a maximum of four stories not to exceed 68’ in height. The height bonus shall not apply to areas zoned –TOD or in a BRT Area as mapped in the Comprehensive Plan. When a property is also zoned with the - Detached frontage, the height bonus shall control.
D6 Frontage and Drive-Thrus Any building that uses the Height Bonus in D5 above must also adhere to the Urban Limited frontage unless otherwise mapped with the Urban General, Shopfront, Green or Green Plus frontage which then controls. Drive-thrus are not permitted on a site when the D5 height bonus is used. A 5 story building utilizing the height bonus herein shall also conform to the requirements for urban plazas set forth in Section 1.5.3.C.
E. Parking Setbacks3
E1 From Primary Street (min) 10’
E2 From Side Street (min) 10’
E3 From Side Lot Line (min) 0’
E4 From Rear Lot Line (min) 3’
E5 From Alley (min)5 4’ or 20’ min
F. Floor Heights
  As prescribed by the Building Type in Chapter 3
G. Transparency
  As prescribed by the Building Type in Chapter 3
F. Additional Requirements
F1 ADU Regulations There shall be no more than one ADU on the same lot as a principal building unless it is located in a Frequent Transit Area as shown on the City’s Comprehensive Plan which would then allow for up to two ADUs on the same lot as a principal dwelling, including attached or internal ADUs. However in a Frequent Transit Area, only one ADU can be attached to the principal building. In the case of a townhome development only one ADU is permitted per principal dwelling.
F2   This development option cannot be used in concert with Compact or Conservation Development option
F3   Lots utilizing this option shall have at least a portion of each lot within the mapped Frequent Transit Area in order to take advantage of any regulations listed herein.

See Sec. 1.5.4.D “Building Setbacks” for specific building elements requirements.
1For Townhouse buildings, C3 shall only apply to the side site boundary.
2For Townhouse buildings, C4 shall only apply to the rear site boundary. A permanently recorded open lot or common area lot of at least 20 feet in width may be used to satisfy Sec. 2.5.1.C.4.
3Parking setbacks shall not apply to driveways serving individual dwelling units or shared between two dwelling units.
4The rent and income limits will follow the Affordable Housing Standards determined annually by the City of Raleigh Housing & Neighborhoods Department. An Affordable Housing Deed Restriction in a form approved by the City shall be filed and recorded in the property’s chain of title by the property owner in the Wake County Register of Deeds prior to the project receiving a certificate of occupancy. The property owner of development approved under this section shall provide an annual report to the City to demonstrate compliance with the requirements of this section. The report shall utilize a form prescribed by the City and shall be submitted in accordance with a schedule set by the City. Affordable units used to meet the requirements of this section shall be constructed concurrently with the project’s market rate units.
5Garages (or a portion thereof) must either be located 4 feet from the travel lane of an alley or rear access drive or be a minimum of 20 feet from the alley or rear access drive. Where parking spaces are located between the garage and the alley or rear access drive, the garage must be located at least 20 feet from the travel lane of an alley or rear access drive.

Supplement Number