Image
Image
RX-, OX-, NX-, CX- | DX- | ||
A. Lot Dimensions | |||
A1 | Area (min) | 2,000 sf | n/a |
A2 | Width (min) | 25' | n/a |
B. Building Setbacks | |||
B1 | From primary street (min) | 10' | 5' |
B2 | From side street (min) | 10' | 5' |
B3 | From side lot line (min) | 5' | 3' |
B4 | From rear lot line (min) | 10' | 10' |
B5 | From alley | 4' or 20' min | 4' or 20' min |
C. Height | |||
C1 | Principal building (max) | 26'/2 stories | 26'/2 stories |
See Sec. 1.5.4.D "Building Setbacks" for specific building element requirements.
D. Additional Requirements for Manufactured Homes to Qualify as Tiny Houses
A Tiny House may be a Manufactured Home as defined in Article 12.2. if it meets all of the following:
- The predominant roofline shall have a pitch of 5:12 or greater.
- The eave projections of the roof must not be less than ten inches (excluding roof gutters) unless the roof pitch is 8:12 or greater.
- The minimum height of the first-story exterior wall must be at least seven feet, six inches.
- Materials used as exterior wall covering shall be of a non-reflective material.
- Foundation skirting shall comply with the requirements set forth in Section 4.5.3.D.
- The Manufactured Home is no greater than 600 square feet in gross floor area.