- Permitted Activity
All structures and uses allowed in the zoning district are permitted in Zone C. - Height
- No structure can be more than 40 feet in height at the Zone C line, as measured from the average pre-development grade measured along the Zone C line.
- Height can increase subject to a 45 degree height plane measured from a height of 40 feet at the Zone C line, extending upward one foot for every additional foot of setback into the site.
- The height plane applies up to 100 feet from the district boundary line.
- Wall Articulation
The rear facade of the building that faces the residential property as described in Sec. 3.5.1.A. is subject to a maximum blank wall area of 30 feet as calculated in Sec. 1.5.10. The blank wall area provisions are not subject to an Design Alternate.Image
Supplement Number
28